HH Series 1-3kVA Double-Conversion Online UPS, PF 1.0, featuring wide input voltage range and plug-and-play design. Built-in LCD display, wide input voltage range and flexible battery charging settings, perfect for office, home and industrial backup power scenarios.
HH Series 1-3kVA Double-Conversion Online UPS, PF 1.0, featuring wide input voltage range and plug-and-play design. Built-in LCD display, wide input voltage range and flexible battery charging settings, perfect for office, home and industrial backup power scenarios.


Feature:
IGBT based rectifier true online double conversion
Microprocessor control optimizes reliability
DSP technology guarantees high performance
Pure sine wave output
Input power factor correction
Unity output power factor
Extremely wide input voltage window
50Hz/60Hz frequency converter mode
ECO and frequency operating voltage possibilities
Graphic LCD display with interactive multilingual user interface
Digital charger technology provides 0-8A charging current
Adjustable charging current/charging mode via LCD panel
Programmable output voltage
Cold start by battery without grid Input
Generator compatible
Extension slot for SNMP, potential-free contacts, remote panel
Parameters
| Model | HH1KS | HH1KL | HH2KS | HH2KL | HH3KS | HH3KL |
| Rating | 1kVA/1000W | 2kVA/2000W | 3kVA/3000W | |||
| Input | ||||||
| Input system | L+N+PE | |||||
| Rated voltage | 208/220/230/240VAC | |||||
| Voltage range |
1. 110Vac~300Vac, 2. 110Vac~176Vac, 3. 280-300Vac, (power limited) |
|||||
| Frequency | 50/60+6HZ (default), ±10HZ (can be set) | |||||
| Power factor | 0.99 | |||||
| Output | ||||||
| Output system | L+N+PE | |||||
| Power factor | 1.0 | |||||
| Voltage | 208/220/230/240VAC | |||||
| Wave Form | Pure Sine Wave | |||||
| Voltage harmonic distortion (rated input voltage. Rated input frequency) |
≤3% (0~100% linear load) ≤5% (0~100% non-linear load) |
|||||
| Frequency | 50 HZ/60 HZ ±0.05% HZ (Battery Model) | |||||
|
Inverter overload capability (in normal mode, 25℃) |
AC Mode: 30min@102%-110% Load 10min@110%-130% Load 30s@130%~150% Load 200ms@>150% Load Battery Mode: 1min@102%-110% Load 10s@110%-130% Load 3s@130%~150% Load 200ms@>150% Load |
|||||
| Transfer time |
AC mode switch to battery mode : 0ms mains inverter mode switch to bypass mode : 4ms |
|||||
| Battery | ||||||
| Battery | 24Vdc | 36Vdc | 48Vdc | 72Vdc | 72Vdc | 96Vdc |
| Charge | 1K,2K,3K, Current 1A (Default)1-5A Adjustable,1KL,2KL,3KL,5A(1-12A) | |||||
| Interface | ||||||
| RS-232 | Support: Windwos 2000/2003/XP/Vista/2008/7/Linux/Unix and MAC | |||||
| USB | Windows FamIly & MAC | |||||
| Intelligent slot(Optional) | SNMP/AS400 Relay Card/RS485 | |||||
| Environmental parameters | ||||||
| Operating ambient temperature | 0~40℃ | |||||
| Operating environment humidity | 20%~95% (No condensation) | |||||
| Storage temperature | -15~60℃ (Battery: 0~40℃) | |||||
| Altitude | The altitude should not exceed 1000m, derating above1000m, up to 4000m (max), refer IEC62040 | |||||
| Noise | ≤50db | |||||
| Size And Weight | ||||||
| Dimensions (D*W*H) (mm) | 285*144*225 | 395*144*225 | 450*192*352 | 395*144*225 | ||
| Net weight (kg) | 9 | 5 | 17 | 9 | 21.4 | 9 |