HX33 Series 10–300kVA

HX33 high-frequency online UPS ranges from 10kVA to 300kVA. Powered by DSP control and SiC diodes. It supports up to 6 units parallel operation, with reliable overload capacity and flexible charging settings, safeguarding power for data centers, medical, industrial and office facilities.

Send Inquiry

Product Description

HX33 high-frequency online UPS ranges from 10kVA to 300kVA. Powered by DSP control and SiC diodes. It supports up to 6 units parallel operation, with reliable overload capacity and flexible charging settings, safeguarding power for data centers, medical, industrial and office facilities.

HX33 Series 10–300kVA

Feature:

DSP technology guarantees high reliability

Output power factor 1

Adapting the latest Silicon carbide diodes to enhance the system efficiency

Dual inputs

Very powerful charger to shorten the recharge time

Adjustable charging current

Parallel up to 6 units with common battery pack

5* color touch type LCD display

Optional programmable relay dry contact card

Voice warning / error code notice

High overload capability

Adjustable battery design

Dynamic password feature optimizes service performance

Power walk-in function

 

Parameter

MODEL 10K(L)* 20K(L)* 30K(L) 40K(L) 60K(L) 80K(L) 100K(L) 120K(L) 160K(L) 200K(L) 240K(L) 300K(L)
PHASE 3-phase in /3-phase out
CAPACITY 10KVA/10K 20KVA/20K 30KVA/30K 40KVA/40K 60KVA/60K 80KVA/80K 100KVA/100K 120KVA/120K 160KVA/160K 200KVA/200K 240KVA/240K 300KVA/300K
INPUT  
Nominal Voltage

3×380/400/415VAC (3Ph+N)

or220/230/240VAC (1Ph+N)

3×380/400/415VAC (3Ph+N)
Voltage Range

190 - 520 VAC (3-phase) @ 50% load

305 - 478 VAC (3-phase) @ 100% load

110-300VAC @50%load; 190-276VAC @100%load 110 - 300 VAC @ 50% load; 184 - 276 VAC @ 100% load
Frequency Range 46~54Hz or 56~64Hz 40Hz ~ 70Hz
Power Factor ≥0.99@100%Load
Distortion Harmonic (THDi) <4% at full linear load
OUTPUT  
Output Voltage 3×380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N)
AC Voltage Regulation (Batt. Mode) ±1%

≤ ±1% Typical (balanced load)

≤ ±2% Typical (unbalanced load)

Frequency Range (Synchronized Range)

Frequency Range (Batt. Mode)

 

46~54Hz or 56~64Hz 50 / 60Hz
50Hz ± 0.1Hz or 60Hz ± 0.1Hz 46Hz ~ 54Hz or 56Hz ~ 64Hz
Current Crest Ratio 3:1(max.)
Harmonic Distortion ≤2% THD (Linear Load); ≤ 5% THD (Non-linear Load) ≤2% THD (Linear Load); ≤ 4% THD (Non-linear Load)
Transfer Time AC Mode to Batt. Mode Zero
Inverter to Bypass Zero
Waveform (Batt. Mode) Pure Sine wave
Overload Capability AC Mode 100-110% for 60min,110-125%for 10min,125%~150% 1min,>150% immediately
Battery Mode ≤110% for 1 hour,111-125% for 1min and >150% for 200ms
EFFICIENCY  
AC Mode 95.5% 96% 95.5% 96% 95.5%
ECO Mode 98.5% 99% 95.8%
Battery Mode 94.5% 95.5% 94.5% 95.5% 94.5%
BATTERY / CHARGER  
Standard Model Battery Type 12V/9 Ah 12V/7 Ah 12V/9 Ah N/A
Numbers (10+10)pcs (16+16)pcs (16+16)pcs × 2 strings
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current (max.) 1A (Default) 2A (Default)
Charging Voltage +/-136.5 VDC +/-218 VDC

+/-192 V ~ +/-240 V (Selectable)

Maximum: +/-240 V (12V × 40Pcs)  

Minimum: +/-192V (12V × 32Pcs)

Long-run Model Battery Type Depending on the capacity of external batteries
Numbers ±8-10 ±16-20 ±16~ ±20 (Adjustable)  
Charging Current (max.) 1A~18A (Adjustable) 1A~12A (Adjustable) 1A~18A (Adjustable) 18A (Adjustable) 24A (Adjustable) 36A (Adjustable) 54A (Adjustable) 72A (Adjustable) 90A (Adjustable)
Charging Voltage

+/-13.65V*N

(N=8~10)

+/-13.65V*N

(N=16~20)

 
INDICATORS  
LCD Panel UPS status, Load level, Battery level, input/Output voltage, Discharge timer, and Fault conditions            790*360*1010
PHYSICAL  
Standard Model Dimension, D×W×H (mm) 630 × 250 × 826 815 × 300 × 1000                
Net Weight (kgs) 80 133 207 233                
Long-run Model Dimension, D×W×H (mm) 630 × 250 × 826 815 × 300 × 1000 430×1000×1200 600×1000×1200 600×1100×1475
Net Weight (kgs) 25 37 55 56 74 125 169 249 360 396
Operation Temperature 0-40℃
Operation Humidity <95% and non-condensing
Altitude*c* 0~1500m at full load
Noise Level Less than 62dB @ 1Meter Less than 65dB @ 1Meter Less than 70dB @ 1Meter   Less than 63 dB@1 Meter Less than 65dB@1 Meter
MANAGEMENT  
Smart Rs-232/USB Support Windows family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser

Send Inquiry

For inquiries about our products or pricelist, please leave your email to us and we will be in touch within 24 hours.
Verify Code